Sunday, August 28, 2016

OTDR Setup - Index of Refraction & Fiber Distance


Picture
All OTDRs regardless of brand have four basic setup requirement i.e. the OTDR user is required to key in these four basic data parameters into OTDR in order to get good and accurate fiber trace analysis.

The required data parameters are :-

  1. Testing Range - Refer to Article HERE
  2. Pulse Width - Refer to Article HERE
  3. Index of Refraction 
  4. Averaging Time
Index of Refraction
Picture
The relationship between distance and velocity or speed is as shown below -
You can review previous article on Index of Refraction HERE or HERE

As previously mentioned index of refraction measures the speed of light in optical medium. It is a function of velocity of light in vacuum and velocity of light in the opticel fiber medium or simply stated as below -
Picture
Velocity of light in fiber optics can be further expressed in terms of velocity of light in vacuum and index of refraction. This is done by rearranging the index of refraction equation as stated above.
Picture
Knowing that C or velocity of light in vacuum is a constant value
Picture
Then the distance of fiber optics as measured by OTDR can be simplied as shown below
Picture
The index of refraction, n,  is a known value which can be obtained from the fiber optics manufacturer. While t , OTDR pulse width  and its backscatter light travelling time , can be measured by OTDR automatically ie. the initial time laser pulse width launched into fiber optics and time taken by backscattered light returned back into OTDR.

Therefore, the measured of fiber optics distance is a function of index of refraction.
As value of IOR increases the measured fiber optic distance or length is getting shorter.
Picture
As value of IOR decreases the measured fiber optic distance or length is getting longer.
Picture
If the OTDR index of refraction does not match to that of fiber optics under testing IOR then the OTDR distance traces might show the incorrect results.

If the fiber optics under testing IOR is not known, then the end-user can use the OTDR default  IOR setting.

Typical fiber optics IOR value is between 1.4000 to 1.6000

Picture
Rule of Thumb
Always obtain the fiber optics Index of Refraction values from corresponding fiber optics manufacturer.

No comments:

Post a Comment